ADE7769
When selecting a suitable F 1–4 frequency for a meter design, the
frequency output at I MAX (maximum load) with a meter constant
of 100 imp/kWh should be compared with Column 4 of Table 9.
The closest frequency in Table 9 determines the best choice of
frequency (F 1–4 ). For example, if a meter with a maximum
current of 25 A is being designed, the output frequency on F1
and F2 with a meter constant of 100 imp/kWh is 0.153 Hz at 25
A and 220 V (from Table 8). In Table 9 the closest frequency to
The no-load condition is indicated with CF output pulse
remaining logic high, as shown in Figure 28.
ACTIVE POWER
NO-LOAD
THRESHOLD
0.153 Hz in Column 4 is 0.176 Hz. Therefore, as shown in Table
5, F3 (3.43 Hz) is selected for this design.
0W
TIME
Frequency Outputs
Figure 2 shows a timing diagram for the various frequency
outputs. The F1 and F2 outputs are the low frequency
outputs that can be used to directly drive a stepper motor or
electromechanical impulse counter. The F1 and F2 outputs
provide two alternating low frequency pulses. The F1 and F2
pulse widths (t 1 ) are set such that if they fall below 240 ms
(0.24 Hz), they are set to half of their period. The maximum
output frequencies for F1 and F2 are shown in Table 6.
The high frequency CF output is intended to be used for
communications and calibration purposes. CF produces a
90-ms-wide active high pulse (t 4 ) at a frequency proportional to
active power. The CF output frequencies are given in Table 7.
As with F1 and F2, if the period of CF (t 5 ) falls below 180 ms,
the CF pulse width is set to half the period. For example, if the
CF frequency is 20 Hz, the CF pulse width is 25 ms.
When high frequency mode is selected (that is, SCF = 0,
S1 = S0 = 1), the CF pulse width is fixed at 35 μs. Therefore,
t 4 is always 35 μs, regardless of output frequency on CF.
NO-LOAD THRESHOLD
The ADE7769 includes a no-load threshold and start-up
current feature, which eliminates any creep effects in the meter.
CF FREQUENCY PROPORTIONAL TO POWER
CF
Figure 28. No-Load Indication Using ADE7769
NEGATIVE POWER INFORMATION
The ADE7769 detects when the current and voltage channels
have a phase shift greater than 90°. This mechanism can detect
an incorrect meter connection or the generation of negative
power. The REVP pin output goes active high when negative
power is detected and active low if positive power is detected.
The REVP pin output changes state as a pulse is issued on CF.
EVALUATION BOARD AND REFERENCE DESIGN
BOARD
An evaluation board can be used to verify the functionality and
the performance of the ADE7769. Download the documenta-
tion for the board from http://www.analog.com/ADE7769.
In addition, the reference design board ADE7769ARN-REF
and Application Note AN-679 can be used in the design
of a low cost watt-hour meter that surpasses IEC62053-21
accuracy specifications. The application note can be
downloaded from http://www.analog.com/ADE7769.
The ADE7769 is designed to issue a minimum output
frequency. Any load generating a frequency lower than this
minimum frequency does not cause a pulse to be issued on F1
or F2. The minimum output frequency is given as 0.00244% for
each of the F 1–4 frequency selections (see Table 5).
For example, for an energy meter with a meter constant of
100 imp/kWh on F1, F2 using F 3 (3.43 Hz), the minimum
output frequency at F1 or F2 would be 0.00244% of 3.43 Hz or
8.38 × 10 –5 Hz. This would be 2.68 × 10 –3 Hz at CF (32 × F1 Hz)
when SCF = S0 = 1, S1 = 0. In this example, the no-load
threshold would be equivalent to 3 W of load or a start-up
current of 13.72 mA at 220 V. Compare this value to the
IEC62053-21 specification which states that the meter must
start up with a load equal to or less than 0.4% Ib. For a 5 A (Ib)
meter, 0.4% of Ib is equivalent to 20 mA.
Rev. A | Page 16 of 20
相关PDF资料
ADM8843ACPZ-REEL7 IC LED DRVR WHITE BCKLGT 16LFCSP
ADP1653ACPZ-R7 IC LED DRVR PHOTO FLASH 16-LFCSP
ADP1712-EVALZ BOARD EVALUATION ADP1712
ADP1720-EVALZ BOARD EVAL FOR ADP1720-ADJ
ADP2140CPZ-REDYKIT REDYKIT 2 BOARDS ADP2140ACPZ
ADP3110AKRZ-RL IC MOSFET DRIVER DUAL 12V 8SOIC
ADP3120AJCPZ-RL IC MOSFET DRIVER DUAL 12V 8-DFN
ADP3121JRZ-RL IC MOSFET DRIVER DUAL 12V 8SOIC
相关代理商/技术参数
ADE7816 制造商:AD 制造商全称:Analog Devices 功能描述:Six Current Channels, One Voltage Channel
ADE7816ACPZ 功能描述:IC POWER METER 3 PHASE 40LFCSP RoHS:是 类别:集成电路 (IC) >> PMIC - 能量测量 系列:- 产品培训模块:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 标准包装:2,500 系列:*
ADE7816ACPZ-RL 功能描述:IC ENERGY METERING 40LFCSP RoHS:是 类别:集成电路 (IC) >> PMIC - 能量测量 系列:- 产品培训模块:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 标准包装:2,500 系列:*
ADE7853ACPZ 制造商:Analog Devices 功能描述:
ADE7854AACPZ 功能描述:IC ENERGY METERING 3PH 40LFCSP 制造商:analog devices inc. 系列:- 包装:托盘 零件状态:有效 输入阻抗:400 千欧 测量误差:0.2% 电压 - I/O 高:2V,2.4V 电压 - I/O 低:0.4V,0.8V 电流 - 电源:20mA 电压 - 电源:2.8 V ~ 3.7 V 表计类型:3 相 工作温度:-40°C ~ 85°C 安装类型:表面贴装 封装/外壳:40-WFQFN 裸露焊盘,CSP 供应商器件封装:40-LFCSP-WQ(6x6) 标准包装:1
ADE7854AACPZ-RL 功能描述:IC ENERGY METER MULTIFUN 40LFCSP 制造商:analog devices inc. 系列:- 包装:带卷(TR) 零件状态:有效 输入阻抗:400 千欧 测量误差:0.2% 电压 - I/O 高:2V,2.4V 电压 - I/O 低:0.4V,0.8V 电流 - 电源:20mA 电压 - 电源:2.8 V ~ 3.7 V 表计类型:3 相 工作温度:-40°C ~ 85°C 安装类型:表面贴装 封装/外壳:40-WFQFN 裸露焊盘,CSP 供应商器件封装:40-LFCSP-WQ(6x6) 标准包装:2,500
ADE7854ACPZ 功能描述:IC ENERGY METERING 3PH 40LFCSP RoHS:是 类别:集成电路 (IC) >> PMIC - 能量测量 系列:- 产品培训模块:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 标准包装:2,500 系列:*
ADE7854ACPZ-RL 功能描述:IC ENERGY METERING 3PH 40LFCSP RoHS:是 类别:集成电路 (IC) >> PMIC - 能量测量 系列:- 产品培训模块:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 标准包装:2,500 系列:*